00136373_0
Expansion module EM-LIGHT


00133883_0
Connection socket for lighting


00133198_0
Buttons on the control panel to switch the lighting on/off
① Fume cupboard lighting


00136373_0
00133883_0
00133198_0

EM-LIGHT

For the simple connection of lighting to an EASYLAB fume cupboard controller

Expansion module with a wired socket for the connection of lighting and for switching the lighting on/off using the control panel

  • Lighting can be switched on/off using an EASYLAB control panel
  • Socket for the connection of fume cupboard or room lighting (230 V)
  • Only in connection with expansion module EM-TRF or EM-TRF-USV
  • Socket on the outside of the controller casing
  • Plug-in connection for the lighting, e.g. fume cupboard lighting

Application

Application

  • Expansion module Type EM-LIGHT for the EASYLAB system
  • Simple connection of lighting (230 V) to a wired socket on the controller casing
  • Control of fume cupboard lighting using the control panel
  • For fume cupboard controllers EASYLAB TCU3 with expansion module EM-TRF or EM-TRF-USV
  • Use for fume cupboards

Special characteristics

  • Control of fume cupboard lighting using the control panel
  • Simple connection of lighting to a wired socket on the controller casing
  • Socket is on the outside of the casing; the casing need not be opened
  • Plug-in connection cable of the fume cupboard lighting is simply connected to the socket

Description

Parts and characteristics

  • Socket WAGO WINSTA Midi, 770 series
  • Socket with plug-in connection cables, 230 V

Useful additions

  • EasyConnect: Configuration software for the commissioning and diagnosis of EASYLAB components

Construction features

  • Socket suitable for the dedicated opening in the controller casing
  • Push-in type socket, no tools required
  • Cables suitable for connection to TCU3 in combination with EM-TRF or EM-TRF-USV
  • Cables with wire end sleeves and text labels for marking the terminals to be used

Informaţii tehnice

  • Function
  • Technical data
  • Specification text
  • Order code
EM-LIGHT 00133880_0
① Mounting socket
② Text label with ID of the terminal on the board of the EASYLAB TCU3 and the EM-TRF or EM-TRF-USV


The EM-LIGHT expansion module provides a socket (WAGO WINSTA Midi, 770 series) for the connection of lighting using a plug-in cable. For this purpose, the expansion module is connected to the terminals of the EM-TRF or EM-TRF-USV for 230 V AC and to a digital output of the TCU3 controller. The lighting can then be switched on/off using the control panel.

Supply voltage230 V AC, connection to EM-TRF or EM-TRF-USV
Maximum switching current12 A; switch-on current 25 A max.
Operating temperature0 – 50 °C
IEC protection classI (protective earth)
Protection levelIP 20
EC conformityEMC to 2004/108/EU, low voltage to 2006/95/EU


Expansion module for the EASYLAB controller TCU3 (connected to 230 V), for the simple connection of lighting to a wired socket (230 V)

Control of lighting (typically fume cupboard lighting) using the control panel.

Special characteristics

  • Control of fume cupboard lighting using the control panel
  • Simple connection of lighting to a wired socket on the controller casing
  • Socket is on the outside of the casing; the casing need not be opened
  • Plug-in connection cable of the fume cupboard lighting is simply connected to the socket

Technical data

  • Supply voltage 230 V AC, connection to EM-TRF or EM-TRF-USV
  • Switching current 12 A max.
  • Operating temperature 0 ...+50 °C
  • Protection level IP 20

em-light

Descărcări fişiere

informaţii produs

production {"X-Frame-Options"=>"SAMEORIGIN", "X-XSS-Protection"=>"1; mode=block", "X-Content-Type-Options"=>"nosniff", "X-Download-Options"=>"noopen", "X-Permitted-Cross-Domain-Policies"=>"none", "Referrer-Policy"=>"strict-origin-when-cross-origin", "Content-Security-Policy"=>"frame-ancestors 'self' https://api.scrivito.com https://punchoutcommerce.com https://www.trox.de https://trox-extern.com https://psp40.onventis.com https://psp22.onventis.com https://trox4u.troxgroup.com", "Strict-Transport-Security"=>"max-age=31536000; includeSubDomains", "Content-Type"=>"text/html; charset=utf-8"}

Distribuie pagina

Recomandaţi această pagină

Recomandaţi această pagină prin trimiterea unui link prin mail.

Câmpurile marcate cu (*) sunt obligatorii.

Distribuie pagina

Vă mulţumim pentru recomandare!

Recomandarea dumneavoastră a fost expediată şi va fi primită în curând.


Contact

Suntem aici pentru dumneavoastră

Vă rugăm să exprimaţi mesajul dumneavoastră şi tipul de cerere
Tel.: +40 31 82 43 041 | Fax: +40 31 82 43 040

Câmpurile marcate cu (*) sunt obligatorii.

Contact

Vă mulţumim pentru mesaj!

Mesajul dumneavoastră este trimis şi va fi procesat în curând.
Departamentul nostru de Cereri Service o să vă contacteze în cel mai scurt timp Pentru întrebări generale privind produsele sau serviciile puteţi suna şi la:
Tel.: +40 31 82 43 041 | Fax: +40 31 82 43 040

Contact

Suntem aici pentru dumneavoastră

Vă rugăm să exprimaţi mesajul dumneavoastră şi tipul de cerere
Tel.: +40 31 82 43 041 | Fax: +40 31 82 43 040

Attachment (max. 10MB)

Câmpurile marcate cu (*) sunt obligatorii.

Contact

Vă mulţumim pentru mesaj!

Mesajul dumneavoastră este trimis şi va fi procesat în curând.
Departamentul nostru de Cereri Service o să vă contacteze în cel mai scurt timp Pentru întrebări generale privind produsele sau serviciile puteţi suna şi la:
Tel.: +40 31 82 43 041 | Fax: +40 31 82 43 040